Our production has a modular character. Various combinations of meters and other components successfully cover a wide range of applications in industry, water management, and many other areas. Upon request, we will be happy to offer you a suitable configuration tailored for your application. If you want to better orient yourself in the products of our company, some typical sets proven in practice follow. However, this is far from a complete list of all possible combinations.

Measurement of oxygen and temperature in the activation tank (in the sludge regeneration tank) of the WWTP

A classic set with an optical oxygen sensor in a robust rod-style probe, with the option of automatic cleaning of the sensor. In parentheses, the variant for two measured locations (reservoirs).

  • 1x MFD88 analyzer configured for 1x(2x) oxygen and temperature measurement, optional 2x relay outputs
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x(2x) submersible probe SPO41K or SPO41MEK (with automatic cleaning)
  • 1x(2x) oxygen and temperature sensor CSOT53PS
  • 1x(2x) MUT11B clamp

Measurement of oxygen and temperature in the activation tank (in the sludge regeneration tank) of the WWTP - lightweight version

A simple set with a freely suspended optical oxygen sensor. In parentheses, the variant for two measured locations (reservoirs).

  • 1x MFD88 analyzer configured for 1x(2x) oxygen and temperature measurement, optional 2x relay outputs
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x(2x) oxygen and temperature sensor CSOT63-88
  • 1x(2x) MUT14 clamp

Measurement of oxygen and temperature in the activation tank (in the sludge regeneration tank) of the WWTP - minimum version

The simplest set consisting only of a freely suspended optical oxygen sensor. This variant is not a full-fledged meter. It requires external power supply and provides only just uncalibrated 4-20 mA output. Suitable only in connection with another system supporting measurement calibration.

Oxygen and temperature measurement for aerobic sludge sanitation

A set with an optical oxygen sensor in an open tank or in a pipe, for an extended range of working temperatures.

  • 1x MFD88 analyzer configured for 1x oxygen and temperature measurement
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x submersible probe SPO41K (for open tank), or sensor sleeve PE G3/4K (for a pipe)
  • 1x oxygen and temperature sensor CSOT53PSN
  • 1x MUT11B clamp (only if the probe SPO41 is used)

Measurement of oxygen and temperature for surface waters - rivers, ponds, reservoirs

Set with automatically cleaned optical oxygen sensor. In parentheses, the variant for two measured locations.

  • 1x MFD88 analyzer configured for 1x(2x) oxygen and temperature measurement
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x(2x) submersible probe SPO41MEK with automatic cleaning
  • 1x(2x) oxygen and temperature sensor CSOT53PS
  • 1x(2x) MUT11B clamp (if needed)

Oxygen and temperature measurement for water treatment plants - raw water

A set with automatically cleaned optical oxygen sensor, water sample supplied by hose.

  • 1x MFD88 analyzer configured for 1x oxygen and temperature measurement
  • 1x flow-through probe SPR41ME with automatic cleaning
  • 1x oxygen and temperature sensor CSOT53PL

Oxygen and temperature measurement for fish farming technologies

Sets with automatically cleaned optical oxygen sensors in robust probes, for 1 - 4 measurement points. Alternatives of measurement directly in the tank, or by feeding a water sample through a hose.

  • 1x MFD88 analyzer
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1-4x submersible probe SPO41MEK (in the tank), or flow-through probe SPR41MEK (sample through a hose)
  • 1-4x oxygen and temperature sensor CSOT53PS
  • 1-4x MUT11B clamp (if needed, only in the case of SPO41MEK probes)

Oxygen and temperature measurement for fish farming technologies - without cleaning

A simplified set with freely suspended optical oxygen sensors directly in tanks, where there is no need for frequent cleaning of the sensors. The device supports configurations of 1 - 12 measured points (more than 4 outputs only available via the MODBUS interface).

  • 1x MFD88 analyzer
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1-12x oxygen and temperature sensor CSOT63-88
  • 1-12x MUT14 clamp (if needed)

Measurement of pH in neutralization tanks

A set with glass pH electrode in a robust rod-style probe with automatic sensor cleaning. Measurement assumed in an open tank, in parentheses the variant for two measurement locations. (Note: Glass sensors are not suitable for measurements in the presence of fluoride ions.)

  • 1x MFD88 analyzer configured for 1x(2x) pH measurement
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x(2x) submersible probe SPO41MEK with automatic cleaning
  • 1x(2x) pH sensor 01-30GK
  • 1x(2x) temperature sensor TTK21PS (if temperature correction is required)
  • 1x(2x) MUT11B clamp (if needed)

pH measurement for water treatment plants - raw water, lime dosing, flocculant dosing

A set with glass pH electrode, with automatic cleaning of the sensor. Supply of the water sample through a hose, the variant for two measured locations is given in brackets.

  • 1x MFD88 analyzer configured for 1x(2x) pH measurement
  • 1x(2x) flow-through probe SPR41ME with automatic cleaning
  • 1x(2x) pH sensor 01-30G
  • 1x(2x) temperature sensor TTK21PL (if temperature correction is required)

pH measurement for water treatment plants - treated water

A set with glass pH electrode in a flow-through probe, or in a cost-saving flow-through unit. Supply of water sample through a hose, no automatic cleaning of the sensor. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) pH measurement
  • 1x(2x) flow-through probe SPR42, or flow-through unit PB42V with PK41 junction box
  • 1x(2x) pH sensor 01-29G (for SPR42) or 01-29GK (for PB42V)
  • 1x(2x) temperature sensor TTK21PS (if temperature correction is required)

Measurement of pH (and temperature) for WWTP - raw water

Classic set with a glass pH electrode in a rod-style probe, for measurements in a tank or channel with an open surface. The spherical cover over the sensor helps self-cleaning by flowing water (mechanical cleaning is not recommended due to the usual presence of fibrous substances).

  • 1x MFD88 analyzer configured for 1x pH measurement
  • 1x submersible probe SPO41K with spherical cover
  • 1x pH sensor 01-29GK
  • 1x temperature sensor TTK21PS (if temperature correction is required)
  • 1x MUT11B clamp

Measurement of pH (and temperature) for WWTP - raw water (lightweight version)

A cost-saving set with a glass pH electrode in a suspended miniature probe. The saving of space and price is redeemed by the lower comfort of maintenance.

  • 1x MFD88 analyzer configured for 1x pH measurement
  • 1x suspension probe SHI63
  • 1x pH sensor 521-BNC
  • 1x MUT14 clamp

Measurement of pH and temperature for fish farming technologies

A cost-saving set with glass pH electrodes in suspended miniature probes. A single device supports up to 12 measurement points (more than 4 outputs only available via the MODBUS interface).

ORP measurement for water treatment plants - raw water, control after permanganate dosing

ORP measurement with automatic cleaning of the sensor, alternatives with supply of water sample by hose or for open tank. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) ORP measurement, optional 2x relay outputs
  • 1x(2x) flow-through probe SPR41ME or submersible probe SPO41ME with automatic cleaning
  • 1x(2x) ORP sensor Pt271T

ORP and pH measurement for water treatment plants

Combination of both usual measurements in a single device. The variant with automatic sensor cleaning is suitable for raw water, or for other places in the technology where lime, flocculant, etc. are dispensed.

  • 1x MFD88 analyzer configured for 1x ORP + pH measurements, optional 2x relay outputs
  • 2x flow-through probe SPR41ME with automatic cleaning
  • 1x ORP sensor Pt271T
  • 1x pH sensor 01-30G
  • 1x temperature sensor TTK21PL (if temperature correction is required for pH measurement)

ORP measurement for WWTP

A set with an automatically cleaned sensor in a rod-style probe, for measurements in a tank or channel with an open surface. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) ORP measurement, optional 2x relay outputs
  • For outdoor installation 1x MUT13V clamp with protective cover
  • 1x(2x) submersible probe SPO41MEK with automatic cleaning
  • 1x(2x) ORP sensor Pt271TK
  • 1x(2x) MUT11B clamp

Conductivity (and temperature) measurement in pipes

A set for measuring pure water with a glass sensor inserted directly into the pipe using a simple cover, or installed with a durable stainless steel probe. Due to the difficulty of cleaning, this variant is not suitable if there is any source of contamination of the sensor. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) conductivity measurement
  • 1x(2x) sensor sleeve PE G3/4D or insertion probe SVK42
  • 1x(2x) conductivity sensor C21 or C29 (if temperature correction is required)
  • 1x(2x) PK41 junction box

Measurement of conductivity (and temperature) in open tanks

A set for measurements in reservoirs and channels with an open surface. Automatic cleaning of the sensors enables measurement even in heavily contaminated waters, but due to the use of plastic parts and stainless steel electrodes, this variant is not suitable for high temperatures and aggressive solutions. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) conductivity measurement
  • 1x(2x) submersible probe SPO41MEK with automatic cleaning, or SPO41K (no cleaning)
  • 1x(2x) conductivity sensor CS21K
  • 1x(2x) temperature sensor TTK21PS (if temperature correction is required)
  • 1x(2x) MUT11B clamp (if needed)

Measurement of free chlorine (or free active chlorine) in water treatment plants

A set with sensor in a cost-saving flow-through unit, suitable for clean water. Water sample supplied with a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) chlorine measurement
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) CSUT43PS-R sensor (or CSCT43PS-R for free active chlorine measurement)

Measurement of free chlorine (or free active chlorine) and pH in water treatment plants

A set with a pair of sensors in a cost-saving flow-through unit, suitable for clean water. Water sample supplied with a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) chlorine and 1x(2x) pH measurements
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) CSUT43PS-R sensor (or CSCT43PS-R for free active chlorine measurement)
  • 1x(2x) pH sensor 01-29GK

Measurement of pH, ORP and chlorine for swimming pools (with possibility of direct dosage control)

Measurement of a trio of common pool water parameters in a single compact block with water sample supplied through a tube. The dosage of chemicals may also be directly controlled, usually to achieve the correct pH and chlorine values. The option listed in parentheses serves two pools within the same building, but is limited to a maximum of 4 outputs by a 4-20 mA current loop and a maximum of 4 relays.

  • 1x MFD88 analyzer configured for 1x(2x) pH + ORP + Chlorine, optional 2x(4x) relay outputs (direct dosage control)
  • 1x(2x) flow-through unit PB43V
  • 2x(4x) PK41 junction box
  • 1x(2x) ph sensor 01-29GK
  • 1x(2x) ORP sensor Pt271TK
  • 1x(2x) clorine and temperature sensor CSUT43PS

Measurement of pH and chlorine for swimming pools (with possibility of direct dosage control)

Measurement of the two most important pool water parameters in a single compact block with water sample supplied through a tube. The dosage of chemicals may also be directly controlled. The option listed in parentheses serves two pools within the same building, but is limited to a maximum of 4 outputs by a 4-20 mA current loop and a maximum of 4 relays.

  • 1x MFD88 analyzer configured for 1x(2x) pH + Chlorine, optional 2x(4x) relay outputs (direct dosage control)
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) ph sensor 01-29GK
  • 1x(2x) clorine and temperature sensor CSUT43PS

Measurement of chlorine dioxide in water treatment plants

A set with sensor in a cost-saving flow-through unit, suitable for clean water. Water sample is supplied through a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) chlorine dioxide
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) sensor CSDT43PS-R

Measurement of chlorine dioxide and pH in water treatment plants

A set with a pair of sensors in a cost-saving flow-through unit, suitable for clean water. Water sample is supplied through a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) chlorine dioxide and 1x(2x) pH
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) sensor CSDT43PS-R
  • 1x(2x) ph sensor 01-29GK

Ozone measurement in water treatment plants

A set with sensor in a cost-saving flow-through unit, suitable for clean water. Water sample is supplied through a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) ozone
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) sensor CSZT43PS-R

Ozone and pH measurement in water treatment plants

A set with a pair of sensors in a cost-saving flow-through unit, suitable for clean water. Water sample is supplied through a tube. The variant for two measured locations is given in parentheses.

  • 1x MFD88 analyzer configured for 1x(2x) ozone and 1x(2x) pH
  • 1x(2x) flow-through unit PB42V
  • 1x(2x) PK41 junction box
  • 1x(2x) sensor CSZT43PS-R
  • 1x(2x) ph sensor 01-29GK

Measurements by ISE sensors in a water sample taken from a pipeline

A set for measurements with various ion-selective electrodes in industrial environments. The water sample is supplied and removed through a hose. These applications must be carefully considered in light of the relatively demanding maintenance of ISE sensors and the required frequency of sensor cleaning. The possibility of automatic cleaning of the sensors must be consulted in advance, as some sensors require the use of a separate reference electrode.

Measurements by ISE sensors in a tank or channel with an open surface

A set for measurements with various ion-selective electrodes in industrial environments. The electrode in a robust rod-style probe is inserted into an open tank or channel. These applications must be carefully considered in light of the relatively demanding maintenance of ISE sensors and the required frequency of sensor cleaning. The possibility of automatic cleaning of the sensors must be consulted in advance, as some sensors require the use of a separate reference electrode.